{"id":5358,"date":"2026-09-14T09:54:25","date_gmt":"2026-09-14T07:54:25","guid":{"rendered":"https:\/\/www.setecna.it\/?p=5358"},"modified":"2026-09-14T09:58:10","modified_gmt":"2026-09-14T07:58:10","slug":"why-ntc-sensors-have-almost-replaced-pt100-and-pt1000","status":"publish","type":"post","link":"https:\/\/www.setecna.it\/en\/why-ntc-sensors-have-almost-replaced-pt100-and-pt1000\/","title":{"rendered":"Why NTC sensors have (almost) replaced Pt100 and Pt1000"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Have you noticed? Electronic boards used to be dominated by Pt100\/Pt1000; today it is almost always NTC.<br>And yet &#8220;on paper&#8221; NTC looks like the worse choice.<br>Pt100\/Pt1000 sensors (the PTC family) are accurate and, above all, linear: a direct match between resistance and temperature. A Pt100 reads 100 \u03a9 at 0 \u00b0C and rises by 0.385 \u03a9\/\u00b0C &#8230; zero point three eight five &#8230; (the Pt1000 with coefficients \u00d710). Read 103.85 \u03a9 \u2192 10 \u00b0C. Simple.<br>NTC sensors are the opposite: resistance falls as temperature rises (hence the &#8220;N&#8221; for Negative), with a strongly NON-linear curve and complicated formulas. In practice you need conversion tables, which differ for each of the many models available. Typical value: ~10K at room temperature.<br>So: less linear, less &#8220;convenient&#8221;.<br>So why are they now used almost exclusively?<br>1. They cost less<br>2. The acquisition circuit is far simpler =&gt; it costs less<br>&#8220;But these characteristics were just as true 20 years ago, so what changed?&#8221;<br>The electronics changed. Today every board carries powerful microcontrollers, and that has flipped the trade-off.<br>Handling non-linearity with analogue circuits or limited MCUs used to be hard: better an inherently linear probe, even at the cost of more refined signal conditioning.<br>Today linearising in software (with calculations or lookup tables) is trivial: you may as well save on the probe and the circuit.<br>There is also a purely practical installation benefit: the very high working value (10K) makes cable length and cross-section practically irrelevant.<br>With a Pt1000 the wiring makes itself felt; with a Pt100, throwing the reading off by a few degrees (upwards, of course\u2026) is the norm. Four-wire measurement exists, of course \u2014 but it costs even more.<br>That is why, in temperature control, NTC sensors are now the only ones left.<br>Enjoy your work!<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Have you noticed? Electronic boards used to be dominated by Pt100\/Pt1000; today it is almost always NTC.And yet &#8220;on paper&#8221; NTC looks like the worse choice.Pt100\/Pt1000 sensors (the PTC family) are accurate and, above all, linear: a direct match between resistance and temperature. A Pt100 reads 100 \u03a9 at 0 \u00b0C and rises by 0.385&hellip; <br \/> <a class=\"read-more\" href=\"https:\/\/www.setecna.it\/en\/why-ntc-sensors-have-almost-replaced-pt100-and-pt1000\/\">Read more<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[187],"tags":[],"class_list":["post-5358","post","type-post","status-publish","format-standard","hentry","category-education"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Why NTC sensors have (almost) replaced Pt100 and Pt1000<\/title>\n<meta name=\"description\" content=\"Pt100 and Pt1000 are linear and accurate, yet NTC is now used almost everywhere: the technical and economic reasons behind that design choice.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.setecna.it\/en\/why-ntc-sensors-have-almost-replaced-pt100-and-pt1000\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Why NTC sensors have (almost) replaced Pt100 and Pt1000\" \/>\n<meta property=\"og:description\" content=\"Pt100 and Pt1000 are linear and accurate, yet NTC is now used almost everywhere: the technical and economic reasons behind that design choice.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.setecna.it\/en\/why-ntc-sensors-have-almost-replaced-pt100-and-pt1000\/\" \/>\n<meta property=\"og:site_name\" content=\"SETECNA EPC\" \/>\n<meta property=\"article:published_time\" content=\"2026-09-14T07:54:25+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-14T07:58:10+00:00\" \/>\n<meta name=\"author\" content=\"admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.setecna.it\\\/en\\\/why-ntc-sensors-have-almost-replaced-pt100-and-pt1000\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.setecna.it\\\/en\\\/why-ntc-sensors-have-almost-replaced-pt100-and-pt1000\\\/\"},\"author\":{\"name\":\"admin\",\"@id\":\"https:\\\/\\\/www.setecna.it\\\/#\\\/schema\\\/person\\\/bd3166770e0aafb406caa7c10fb85806\"},\"headline\":\"Why NTC sensors have (almost) replaced Pt100 and Pt1000\",\"datePublished\":\"2026-09-14T07:54:25+00:00\",\"dateModified\":\"2026-09-14T07:58:10+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.setecna.it\\\/en\\\/why-ntc-sensors-have-almost-replaced-pt100-and-pt1000\\\/\"},\"wordCount\":295,\"publisher\":{\"@id\":\"https:\\\/\\\/www.setecna.it\\\/#organization\"},\"articleSection\":[\"Education\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.setecna.it\\\/en\\\/why-ntc-sensors-have-almost-replaced-pt100-and-pt1000\\\/\",\"url\":\"https:\\\/\\\/www.setecna.it\\\/en\\\/why-ntc-sensors-have-almost-replaced-pt100-and-pt1000\\\/\",\"name\":\"Why NTC sensors have (almost) replaced Pt100 and Pt1000\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.setecna.it\\\/#website\"},\"datePublished\":\"2026-09-14T07:54:25+00:00\",\"dateModified\":\"2026-09-14T07:58:10+00:00\",\"description\":\"Pt100 and Pt1000 are linear and accurate, yet NTC is now used almost everywhere: the technical and economic reasons behind that design choice.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.setecna.it\\\/en\\\/why-ntc-sensors-have-almost-replaced-pt100-and-pt1000\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.setecna.it\\\/en\\\/why-ntc-sensors-have-almost-replaced-pt100-and-pt1000\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.setecna.it\\\/en\\\/why-ntc-sensors-have-almost-replaced-pt100-and-pt1000\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.setecna.it\\\/en\\\/home-setecna\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Why NTC sensors have (almost) replaced Pt100 and Pt1000\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.setecna.it\\\/#website\",\"url\":\"https:\\\/\\\/www.setecna.it\\\/\",\"name\":\"SETECNA EPC\",\"description\":\"HVAC OEM ELECTRONICS EXPERTS\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.setecna.it\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.setecna.it\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.setecna.it\\\/#organization\",\"name\":\"Setecna EPC srl\",\"url\":\"https:\\\/\\\/www.setecna.it\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.setecna.it\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.setecna.it\\\/wp-content\\\/uploads\\\/2022\\\/06\\\/cropped-cropped-Risorsa-3.png\",\"contentUrl\":\"https:\\\/\\\/www.setecna.it\\\/wp-content\\\/uploads\\\/2022\\\/06\\\/cropped-cropped-Risorsa-3.png\",\"width\":1864,\"height\":186,\"caption\":\"Setecna EPC srl\"},\"image\":{\"@id\":\"https:\\\/\\\/www.setecna.it\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.setecna.it\\\/#\\\/schema\\\/person\\\/bd3166770e0aafb406caa7c10fb85806\",\"name\":\"admin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/836c4d1b1b3fc37f6263e17ce27f322f5113980c9538e658e6c831fd23df7336?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/836c4d1b1b3fc37f6263e17ce27f322f5113980c9538e658e6c831fd23df7336?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/836c4d1b1b3fc37f6263e17ce27f322f5113980c9538e658e6c831fd23df7336?s=96&d=mm&r=g\",\"caption\":\"admin\"},\"sameAs\":[\"https:\\\/\\\/services.setecna.it\"],\"url\":\"https:\\\/\\\/www.setecna.it\\\/en\\\/author\\\/cmarini_k5720zxf\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Why NTC sensors have (almost) replaced Pt100 and Pt1000","description":"Pt100 and Pt1000 are linear and accurate, yet NTC is now used almost everywhere: the technical and economic reasons behind that design choice.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.setecna.it\/en\/why-ntc-sensors-have-almost-replaced-pt100-and-pt1000\/","og_locale":"en_US","og_type":"article","og_title":"Why NTC sensors have (almost) replaced Pt100 and Pt1000","og_description":"Pt100 and Pt1000 are linear and accurate, yet NTC is now used almost everywhere: the technical and economic reasons behind that design choice.","og_url":"https:\/\/www.setecna.it\/en\/why-ntc-sensors-have-almost-replaced-pt100-and-pt1000\/","og_site_name":"SETECNA EPC","article_published_time":"2026-09-14T07:54:25+00:00","article_modified_time":"2026-09-14T07:58:10+00:00","author":"admin","twitter_card":"summary_large_image","twitter_misc":{"Written by":"admin","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.setecna.it\/en\/why-ntc-sensors-have-almost-replaced-pt100-and-pt1000\/#article","isPartOf":{"@id":"https:\/\/www.setecna.it\/en\/why-ntc-sensors-have-almost-replaced-pt100-and-pt1000\/"},"author":{"name":"admin","@id":"https:\/\/www.setecna.it\/#\/schema\/person\/bd3166770e0aafb406caa7c10fb85806"},"headline":"Why NTC sensors have (almost) replaced Pt100 and Pt1000","datePublished":"2026-09-14T07:54:25+00:00","dateModified":"2026-09-14T07:58:10+00:00","mainEntityOfPage":{"@id":"https:\/\/www.setecna.it\/en\/why-ntc-sensors-have-almost-replaced-pt100-and-pt1000\/"},"wordCount":295,"publisher":{"@id":"https:\/\/www.setecna.it\/#organization"},"articleSection":["Education"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.setecna.it\/en\/why-ntc-sensors-have-almost-replaced-pt100-and-pt1000\/","url":"https:\/\/www.setecna.it\/en\/why-ntc-sensors-have-almost-replaced-pt100-and-pt1000\/","name":"Why NTC sensors have (almost) replaced Pt100 and Pt1000","isPartOf":{"@id":"https:\/\/www.setecna.it\/#website"},"datePublished":"2026-09-14T07:54:25+00:00","dateModified":"2026-09-14T07:58:10+00:00","description":"Pt100 and Pt1000 are linear and accurate, yet NTC is now used almost everywhere: the technical and economic reasons behind that design choice.","breadcrumb":{"@id":"https:\/\/www.setecna.it\/en\/why-ntc-sensors-have-almost-replaced-pt100-and-pt1000\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.setecna.it\/en\/why-ntc-sensors-have-almost-replaced-pt100-and-pt1000\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.setecna.it\/en\/why-ntc-sensors-have-almost-replaced-pt100-and-pt1000\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.setecna.it\/en\/home-setecna\/"},{"@type":"ListItem","position":2,"name":"Why NTC sensors have (almost) replaced Pt100 and Pt1000"}]},{"@type":"WebSite","@id":"https:\/\/www.setecna.it\/#website","url":"https:\/\/www.setecna.it\/","name":"SETECNA EPC","description":"HVAC OEM ELECTRONICS EXPERTS","publisher":{"@id":"https:\/\/www.setecna.it\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.setecna.it\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.setecna.it\/#organization","name":"Setecna EPC srl","url":"https:\/\/www.setecna.it\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.setecna.it\/#\/schema\/logo\/image\/","url":"https:\/\/www.setecna.it\/wp-content\/uploads\/2022\/06\/cropped-cropped-Risorsa-3.png","contentUrl":"https:\/\/www.setecna.it\/wp-content\/uploads\/2022\/06\/cropped-cropped-Risorsa-3.png","width":1864,"height":186,"caption":"Setecna EPC srl"},"image":{"@id":"https:\/\/www.setecna.it\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.setecna.it\/#\/schema\/person\/bd3166770e0aafb406caa7c10fb85806","name":"admin","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/836c4d1b1b3fc37f6263e17ce27f322f5113980c9538e658e6c831fd23df7336?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/836c4d1b1b3fc37f6263e17ce27f322f5113980c9538e658e6c831fd23df7336?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/836c4d1b1b3fc37f6263e17ce27f322f5113980c9538e658e6c831fd23df7336?s=96&d=mm&r=g","caption":"admin"},"sameAs":["https:\/\/services.setecna.it"],"url":"https:\/\/www.setecna.it\/en\/author\/cmarini_k5720zxf\/"}]}},"_links":{"self":[{"href":"https:\/\/www.setecna.it\/en\/wp-json\/wp\/v2\/posts\/5358","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.setecna.it\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.setecna.it\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.setecna.it\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.setecna.it\/en\/wp-json\/wp\/v2\/comments?post=5358"}],"version-history":[{"count":2,"href":"https:\/\/www.setecna.it\/en\/wp-json\/wp\/v2\/posts\/5358\/revisions"}],"predecessor-version":[{"id":5361,"href":"https:\/\/www.setecna.it\/en\/wp-json\/wp\/v2\/posts\/5358\/revisions\/5361"}],"wp:attachment":[{"href":"https:\/\/www.setecna.it\/en\/wp-json\/wp\/v2\/media?parent=5358"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.setecna.it\/en\/wp-json\/wp\/v2\/categories?post=5358"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.setecna.it\/en\/wp-json\/wp\/v2\/tags?post=5358"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}